hayward blue essence troubleshootingventure pal backpack field operation 40l hayward blue essence troubleshooting Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. Was working fine until I backwashed and cleaned the basket by the pump. Hi Jim, yes it could be leaking, around the stem that sticks up thru the valve body and attaches to the handle. Could be the use of a clarifier or flocculent that is clogging the sand? Weve had our Hayward for four years now never had any problems.tonight my husband vacuumed the pool then back washed it. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. Any idea why this might be happening? Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. have an old hayward flo lx pump and sounds like it is turning on with a click but wont start sucking the water from the pool through the pump to the filter. Thanks for the comment, impellers dont normally wear out, they either work or they are flat busted and dont work. 1. drain plug "description": "Hayward Pool Heater Troubleshooting Guide - how to step by step approach to determining if the water supply, gas supply, electrical supply or a component of the heater is causing the issue. Motors are hot normally, 140 degrees or so, but if it shuts off and then resets and turns on again after 15-20 mins, it could be overheating, from voltage problems, loose connections, motor board, switch or capacitor wiring problems, or internal winding shorts. Have a Hayward variable that was replaced last year. When incoming pipes or valves are clogged, you can get a surge. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. My first thought is that the breaker may be too small for the amount of amps needed to start each piece of equipment. Flip the switch opposite, and you should be all set. First, I want to ensure the pool is voltage free, thus grounded and all components are bonded, I know many pumps have a zinc plate that actually bonds the water. Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. We recently noticed the plug and cord are getting hot and the rubber is beginning to melt. Is that a result of all the water that got in the equipment during the storm? I found the switch to turn off the capacitor was not operating correctly. Could be a short in the wiring that could be tested with an Ohm meter, for resistance. I have cleaned the rubber gasket, made sure the springs touch to no avail. Hi Deb, SF (Sensor Failure) indicates that the temperature sensor (thermistor) is not getting good data to the circuit board. Step 3: Double check the wires on the flow switch for damage. The issue continue to happen so I called a pool repair technician and he came out and verified that the filter was put together properly and also replaced the O-rings in the backwash valve. The high temp limit that is the pump motor as a thermal overload switch (located at 12 oclock in rear of motor), that will shut the motor down and prevent restart until the overload senses lower temps and resets itself, at which point the pump should turn on again, by itself. Step 1: With your pump running, double-check the positions of your valves. Hayward Blue Essence Troubleshooting, Pool Supplies Near Me Open Now, Breville Tamper Coffee Kit 54mm, Used Cozzia Massage Chair, Power Pole Distribution Block, Signature Custom Cabinetry, hayward blue essence troubleshootinghi-c orange lavaburst bottle hayward blue essence troubleshooting Destacado beach outfit ideas for chubby You can pull out the plunger and inspect, and see how it fits the valve body, at the top, should contact all sides, and be lubed well, twice per year. And you cant rule out a problem with the circuit board either. if one of the clips or orings is missing, that is another cause of passing DE into the pool. Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. Or if pump was off for some time, it can leak water, where it leaks air, when on. Profile, Create a Pool Owner Then the others are 2-high speed and 1-low speed wire see the diagram on this page: http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html. I have a humming noise when plugged in, but can seem to get the cover off. Im having an air leak problem with my pool. The second thing that can cause such a problem is if the pump is starved for water, cavitating, because it is too large (hp) for the piping system, or because incoming valves are closed, or pipes are plugged, or clogged. Im losing my mind. . I think you need two timers, usually, unless it can deliver 240 to the filter pump and 120 to the booster, at the same time. You are also using the diffuser? What can I do? In either case, a new vacuum hose of good quality should fix the issue. Hi Rob, normally sunshine will not cause a motor to overheat, but if it is having other internal issues generating heat, it could push it over the limit. For the leaking underneath, that sounds like the shaft seal SPX1600Z2 or it could be leaking around the plumbing fitting threads, where water exits the pump, and is running down the side of the pump and dripping off the bottom. Does the LED light turn off after 60 seconds? "@context": "https://schema.org/",
Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). that is correct, those are the usual suspects. If any of these readings are outside limits, replace motor. The error code will be cleared upon a valid data exchange between boards, If the limit string opens the heater shuts down and goes into lockout. I changed the sand and it is still occurring. I will try that tonight. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | We would like to show you a description here but the site wont allow us. You need to be really sure about the actual salinity reading. Any suggestions?? Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. Hi, it could be just that, a vibration. The shaft turned with zero resistance. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. Do you know what the suggested torque is for the housing cap screws? 1. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Hi Davy,I have a Hayward pump and its not priming.The basket is only filling up halfway with water. Finally, it could be making the noise at the burner orifice, if one or more is not fully spewing gas, or is not ignited like the rest. Hi Michael, sounds like the capacitor may be bad, located at 9 oclock in the motor rear, replace with exact same MFD rating. Most above ground pool pumps are not self-priming, and mot inground pumps are self-priming. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. My salt was tested today at 3000 and everything else was perfect. Hayward North Star replaces capacitors Twice in a span of 3 month now pool pump not making any noise wondering if I can replace capacitor a third time. Salt Chlorinator Problems - Repair or Replace? - InTheSwim Pool Blog Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. It is a common problem with Hayward Perflex, the symptoms you describe, and is usually clogged fingers. Hi! Profile, Create a Pool Professional Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). The pump is currently configured for 115v. Check that they are tight and havent come loose. I checked the voltage at the back of the motor and have 240 volts. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. So in actuality the pump is only being used 4 months a year for 8 hours a day. But, you know whats not great? Currently it is at pool level. Sounds like maybe youve tried it both ways, at water level and below water level? Hi Davy~ The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Could be too big for the pipe size, although normally I would think that a 1hp should be fine, but do a wheel RPM test on the cleaner (28-32 RPM of the wheel is ideal), and bleed off excess water pressure at the wall fitting. Maybe the GFCI button tripped? Good morning. It has been operating properly in its current setup for atleast 2 years (came with house). When this has been corrected, shut the power down to the pump and rest it after 15 minutes. Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. When I go to backwash the filter pump shuts down. When turned on, it clicks in and off every few seconds. Sean, Hi Sean, no worries. The Aquatrol kind of jumped and the breaker tripped. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Checked breakers etc tried again and it came onbut very loud. And since it was running before (it shut off), its probably not rust. Grids not aligned properly, thus not pushed fully up into manifold Just bought a new Hayward Perflex Series Extended Cycle Filtration Systems filter and cant get the motor to start. Check the motor diagram for the voltage wiring diagram. Yesterday I plugged it in to filter and where the plug goes into the 3 foot heavy duty extension it sparked smoked and created a small flame. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. Could that be the voltage then or is there another possibility? I went out Toto shut it off so I could backwash and add chlorine. What happens if too much air gets in before the high speed kicks in? I even plugged in the old pump and that too did not run? The water level in the pool is high enough, but Im getting a whirlpool in the skimmer basket, and the water returning back into the pool is so powerful, its creating a whirlpool and air bubbles I dont know what else to do? Or maybe the glue that Im assuming is no longer working? I owe you a beer if you are ever around my neck of the woods. Pump is 29 years old so wouldnt surprise me if impeller is failing.
Hi John hot plug? If the pump is too large and powerful for the system and pipe size (and Northstars are BIG pumps), the cavitation can cause the motor to overwork. Hi Bryan, not normal but not uncommon. On the Swim Pro filters, check the two lock nuts under the lid, which secure the pressure gauge and air assembly, and be sure the filter is seated firmly into the base. Recently I started getting a loud vibration hum from my hayward pump. I tried to snake the pump but didnt find anything. If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. Flipped the timer on, water shot up about 10 feet and went all over me and the timer and the breaker blew. Culligan Compatible TFM-36-A Aqua Cleer - 01-0074-02 Reverse Osmosis This is Poolside Chat where every week we answer your questions on how to fix and maintain your swimming pool. dont know if the pump went bad already. If the motor shaft and impeller is spinning freely (not clogged or bound-up), then remove the rear cover to the motor. Grab it and see if it looks/feels loose. 5. very dirty pool filter, Every time the pump is turned on with the timer it trips the circuit breaker. Any new postings here are unlikely to be seen or responded to by other members. There is also a faint burnt odor. I cant imagine paying someone to take 2 bolts off. Amp draw is 15 amps. Even though the motor is only 2 months old and had very little run time, bench running it sounds pretty horrible. Check that the pump lid is on very tight, and that the threaded fitting that screws into the front of the pump has Teflon tape or other thread sealant. If you find out, I would check the owners manual for information related to your symptoms. Press and hold the diagnostic button for 3 to 5 seconds. Our pump is going through this one-off cycle similar to what others are describing. However, many inground pools do not run the pump 24/7, but operate it from 12-18 hrs daily, depending on the need, and the ability of the filtration system and sanitation efforts, etc Some small systems do need to run 24/7, but a properly sized system has a timeclock, to set it to run for around 12 hours per day (less during cool periods, more during hot spells)>.
hayward blue essence troubleshooting